- Turndown ratio up to 1:95 – maximum flexibility
- Up to 20% energy savings compared with competitor products
- Bus connection for Industry 4.0 and building automation
GSI 50 – 350
| Type | GSI 50 | GSI 100 | GSI 180 | GSI 250 | GSI 350 |
|---|---|---|---|---|---|
| Burner output | 3 - 60 kW | 4 - 110 kW | 4 - 166 kW | 4 - 250 kW | 6 - 350 kW |
| Control | continuously variable | continuously variable | continuously variable | continuously variable | continuously variable |
| Product ID no. | CE0085AQ1024 DVGW tested | CE0085AQ1024 DVGW tested | CE0085AQ1024 DVGW tested | CE0085AQ1024 DVGW tested | CE0085AQ1024 DVGW tested |
| Mains connection | 230 V / 50 Hz | 230 V / 50 Hz | 230 V / 50 Hz | 230 V / 50 Hz | 230 V / 50 Hz |
| Motor | 0.07 kW / 0.75 A / 2800 min-1 | 0.07 kW / 0.75 A / 2800 min-1 | 0.07 kW / 0.75 A / 2800 min-1 | 0.07 kW / 0.75 A / 2800 min-1 | 0.45 kW / 3.1 A / 2800 min-1 |
| Gas burner control unit | LMV37 | LMV37 | LMV37 | LMV37 | LMV37 |
| Ignition transformer | 7,000 V / 30 mA | 7,000 V / 30 mA | 7,000 V / 30 mA | 7,000 V / 30 mA | 10,000 V / 30 mA |
| Gas pressure | 20 - 100 mbar | 20 - 100 mbar | 20 - 100 mbar | 20 - 100 mbar | 20 - 100 mbar |
| Gas flow rate | 0.3 - 6 m³/h | 0.4 - 10 m³/h | 0.4 - 16 m³/h | 0.4 - 24 m³/h | 0.6 - 33 m³/h |
| Max. turndown ratio | 1 : 20 | 1 : 28 | 1 : 40 | 1 : 60 | 1 : 58 |
| Weight | 23 kg | 25 kg | 25 kg | 27 kg | 44 kg |
| Burner connection | R ½ " | R ¾ " | R ¾ " | R 1 " | R 1½ " |
| Order no. | 5518 522 204 | 5518 523 206 | 5518 524 206 | 5518 524 217 | 5518 525 202 |
*Pressure stated as gas flow pressure
Special designs: burner design to TRD 412 · with three-phase motor · flame tube extension of 100 - 1000 mm possible · potentiometer with servo motor built in · continuously running fan with differential pressure switch and three-way valve · air intake filter with replaceable filter element
Output ranges in kW (values apply to natural gas, pressure stated as gas flow pressure)
| Type | 20 mbar |
|---|---|
| GSI 50 E/F 0,5 M | 3 - 60 |
| GSI 100 E/F 0,75 M | 4 - 110 |
| GSI 180 E/F 0,75 M | 4 - 166 |
| GSI 250 E/F 1,0 M | 4 - 220 |
| GSI 350 E/F 1,50 M | 6 - 350 |
| GSI 600 E/F 1,50 M | 6 - 578 |
GSI 600 – 1800
| Type | GSI 600 | GSI 900 | GSI 1200 | GSI 1800 |
|---|---|---|---|---|
| Burner output | 6 - 578 kW | 27 - 1080 kW | 30 - 1650 kW | 40 - 1950 kW |
| Control | continuously variable | continuously variable | continuously variable | continuously variable |
| Product ID no. | CE0085AQ1024 DVGW tested | CE0085AQ1024 DVGW tested | CE0085AQ1024 DVGW tested | CE0085AQ1024 DVGW tested |
| Mains connection | 230 V / 50 Hz | 230 V / 400 V / 50 Hz | 230 V / 400 V / 50 Hz | 230 V / 400 V / 50 Hz |
| Burner motor | 0.45 kW / 3.1 A / 2800 min-1 | 1.1 kW / 2.65 A / 2800 min-1 | 2.2 kW / 4.92 A / 2800 min-1 | 3.0 kW / 6.45 A / 2800 min-1 |
| Gas burner control unit | LMV37 | LMV37 | LMV37 | LMV37 |
| Ignition transformer | 1,000 V / 23 mA | 10,000 V / 23 mA | 10,000 V / 23 mA | 10,000 V / 23 mA |
| Gas pressure | 20 - 100 mbar | 20 - 100 mbar | 20 - 100 mbar | 20 - 100 mbar |
| Gas flow rate | 0.6 - 55 m³/h | 2.4 - 98 m³/h | 2.8 - 164 m³/h | 3.8 - 191 m³/h |
| Max. turndown ratio | 1 : 95 | 1 : 40 | 1 : 55 | 1 : 66 |
| Weight | 48 kg | 80 kg | 116 kg | 120 kg |
| Burner connection | R 1½ " | R 1½ " | R 2 " | R 2 " |
| Order no. | 5518 527 202 | 5518 528 210-2 | 5518 529 185 | 5518 529 211 |
Special designs: burner design to TRD 412 · with three-phase motor · flame tube extension of 100 - 1000 mm possible · potentiometer built into the servo motor · continuously running fan with differential pressure switch and three-way valve
Output ranges in kW (values apply to natural gas, pressure stated as gas flow pressure)
| Type | 20 mbar | 25 mbar | 30 mbar |
|---|---|---|---|
| GSI 900 with gas valve train DN 1.5" | 27 - 500 | 27 - 660 | |
| GSI 900 with gas valve train DN 2" | 27 - 550 | 27 - 760 | 27 - 960 |
| GSI 900 with gas valve train DN 65 | 27 - 780 | 27 - 1080 | |
| GSI 1200 with gas valve train DN 2" | 30 - 750 | 30 - 960 | 30 - 1200 |
| GSI 1200 with gas valve train DN 65 | 30 - 1150 | 30 - 1650 | |
| GSI 1200 with gas valve train DN 80 | 30 - 1650 | ||
| GSI 1800 with gas valve train DN 65 | 30 - 1000 | 30 - 1300 | 30 - 1600 |
| GSI 1800 with gas valve train DN 80 | 30 - 1350 | 30 - 1950 | |
| GSI 1800 with gas valve train DN 100 | 30 - 1950 |