.png)
Multi-fuel burners
Industrial burner GOZ
Dual-fuel burner gas/oil – maximum security of supply
Highlights
- Dual-fuel operation – gas and oil in one burner
- Easy switching between gas and oil operation without conversion
- Protection against supply shortages – maximum operational reliability
Fast processing:
Quote within 24 hours · Free technical consultation
Product description
The GOZ series is the answer to the growing demand for fuel independence: one burner – two energy sources. The GOZ dual-fuel burner combines full-scale gas operation, modulating or staged, and oil operation in one compact housing.
The GOZ gas/oil burner is optimised for gas operation and can be used for oil operation for limited periods. Switching between gas and oil operation is straightforward and requires no conversion work. This protects against supply shortages and secures operation even when one supply source is temporarily unavailable.
With an output range of 27 to 3,300 kW, the GOZ is designed for medium to large industrial and heating systems – wherever security of supply is strategically decisive.
Typical applications:
Industrial boilers, steam generators, process heat, critical infrastructure, production plants with high availability requirements
Technical specifications
GOZ/S 100 – 600
| Type | GOZ/S 100 | GOZ/S 180/250 | GOZ/S 350 | GOZ/S 600 |
|---|---|---|---|---|
| Burner output | 27 - 120 kW | 30 - 220 kW | 55 - 325 kW | 87 - 530 kW |
| Control | Gas: continuously modulating or two-stage sliding; oil: two-stage sliding | Gas: continuously modulating or two-stage sliding; oil: two-stage sliding | Gas: continuously modulating or two-stage; oil: two-stage sliding | Gas: continuously modulating or two-stage; oil: two-stage sliding |
| Product ID no. | CE-0085AQ1023 · DVGW tested | CE-0085AQ1023 · DVGW tested | CE-0085AQ1023 · DVGW tested | CE-0085AQ1023 · DVGW tested |
| Mains connection | 230 V / 50 Hz | 230 V / 50 Hz | 230 V / 50 Hz | 230 V / 50 Hz |
| Motor | 0.07 kW / 0.75 A / 2800 min-1 | 0.07 kW / 0.75 A / 2800 min-1 | 0.45 kW / 1.4 A / 2800 min-1 | 0.45 kW / 1.3 A / 2800 min-1 |
| Gas burner control unit | LMV | LMV | LMV | LMV |
| Ignition transformer | 7,000 V / 30 mA | 7,000 V / 30 mA | 10,000 V / 40 mA | 10,000 V / 40 mA |
| Gas pressure | 20 - 100 mbar | 20 - 100 mbar | 20 - 100 mbar | 20 - 100 mbar |
| Gas flow rate | 2.7 - 12 m³/h | 3 - 22 m³/h | 5 - 32 m³/h | 8 - 53 m³/h |
| Turndown ratio | 1 : 4 | 1 : 8 | 1 : 6 | 1 : 6 |
| Weight | 28 kg | 30 kg | 50 kg | 50 kg |
| Burner connection | R ¾ " | R ¾ " / 1 " | R 1½ " | R 1½ " |
| Order no. | 5518 622 001 | 5518 622 002 | 5518 625 002 | 5518 627 004 |
Burner output27 - 120 kW
ControlGas: continuously modulating or two-stage sliding; oil: two-stage sliding
Product ID no.CE-0085AQ1023 · DVGW tested
Mains connection230 V / 50 Hz
Motor0.07 kW / 0.75 A / 2800 min-1
Gas burner control unitLMV
Ignition transformer7,000 V / 30 mA
Gas pressure20 - 100 mbar
Gas flow rate2.7 - 12 m³/h
Turndown ratio1 : 4
Weight28 kg
Burner connectionR ¾ "
Order no.5518 622 001
Burner output30 - 220 kW
ControlGas: continuously modulating or two-stage sliding; oil: two-stage sliding
Product ID no.CE-0085AQ1023 · DVGW tested
Mains connection230 V / 50 Hz
Motor0.07 kW / 0.75 A / 2800 min-1
Gas burner control unitLMV
Ignition transformer7,000 V / 30 mA
Gas pressure20 - 100 mbar
Gas flow rate3 - 22 m³/h
Turndown ratio1 : 8
Weight30 kg
Burner connectionR ¾ " / 1 "
Order no.5518 622 002
Burner output55 - 325 kW
ControlGas: continuously modulating or two-stage; oil: two-stage sliding
Product ID no.CE-0085AQ1023 · DVGW tested
Mains connection230 V / 50 Hz
Motor0.45 kW / 1.4 A / 2800 min-1
Gas burner control unitLMV
Ignition transformer10,000 V / 40 mA
Gas pressure20 - 100 mbar
Gas flow rate5 - 32 m³/h
Turndown ratio1 : 6
Weight50 kg
Burner connectionR 1½ "
Order no.5518 625 002
Burner output87 - 530 kW
ControlGas: continuously modulating or two-stage; oil: two-stage sliding
Product ID no.CE-0085AQ1023 · DVGW tested
Mains connection230 V / 50 Hz
Motor0.45 kW / 1.3 A / 2800 min-1
Gas burner control unitLMV
Ignition transformer10,000 V / 40 mA
Gas pressure20 - 100 mbar
Gas flow rate8 - 53 m³/h
Turndown ratio1 : 6
Weight50 kg
Burner connectionR 1½ "
Order no.5518 627 004
Special designs: burner design to TRD 412 · with three-phase motor · flame tube extension of 100 - 1000 mm possible
BA-5 design: GOZ/S 350 E BA 5: 5518 625 999 · GOZ/S 600 E BA 5: 5518 627 999
Output figures for natural gas H (Ho = 10.35 kWh/m³) / heating oil EL (Ho = 10.57 kWh/kg)
GOZ/S 900 – 3700
| Type | GOZ/S 900 E | GOZ/S 1200 E | GOZ/S 1800 E | GOZ/S 3700 E |
|---|---|---|---|---|
| Burner output | 230 - 1000 kW | 270 - 1450 kW | 300 - 1750 kW | 700 - 3300 kW |
| Control | Gas: continuously modulating or two-stage sliding; oil: two-stage sliding | Gas: continuously modulating or two-stage sliding; oil: two-stage sliding | Gas: continuously modulating or two-stage sliding; oil: two-stage sliding | Gas: continuously modulating or two-stage sliding; oil: two-stage sliding |
| Product ID no. | CE-0085AQ1023 · DVGW tested | CE-0085AQ1023 · DVGW tested | CE-0085AQ1023 · DVGW tested | CE-0085AQ1023 · DVGW tested |
| Mains connection | 230 V / 400 V / 50 Hz | 230 V / 400 V / 50 Hz | 230 V / 400 V / 50 Hz | 400 V / 50 Hz |
| Burner motor | 1.1 kW / 2.65 A / 2800 min-1 | 2.2 kW / 4.92 A / 2800 min-1 | 3.0 kW / 6.45 A / 2800 min-1 | 7.5 kW / 15 A / 2800 min-1 |
| Oil pump motor | 0.55 kW / 1.4 A / 230 V / 400 V | 0.55 kW / 1.4 A / 230 V / 400 V | 0.55 kW / 1.4 A / 230 V / 400 V | 0.8 kW / 2.1 A / 230 V / 400 V |
| Gas burner control unit | LMV | LMV | LMV | LMV |
| Ignition transformer | 10,000 V / 40 mA | 10,000 V / 40 mA | 10,000 V / 40 mA | 10,000 V / 40 mA |
| Gas pressure | 20 - 100 mbar | 20 - 100 mbar | 20 - 100 mbar | 20 - 100 mbar |
| Gas flow rate | 22 - 96 m³/h | 25 - 145 m³/h | 30 - 168 m³/h | 67 - 318 m³/h |
| Turndown ratio | 1 : 4 | 1 : 6 | 1 : 6 | 1 : 5 |
| Weight | 97 kg | 105 kg | 108 kg | 190 kg |
| Burner connection | R 1½ " | R 2 " | R 2 " | R 2½ " |
| Order no. | 5518 628 011 | 5518 629 012 | 5518 629 016 | 5518 629 218 |
Burner output230 - 1000 kW
ControlGas: continuously modulating or two-stage sliding; oil: two-stage sliding
Product ID no.CE-0085AQ1023 · DVGW tested
Mains connection230 V / 400 V / 50 Hz
Burner motor1.1 kW / 2.65 A / 2800 min-1
Oil pump motor0.55 kW / 1.4 A / 230 V / 400 V
Gas burner control unitLMV
Ignition transformer10,000 V / 40 mA
Gas pressure20 - 100 mbar
Gas flow rate22 - 96 m³/h
Turndown ratio1 : 4
Weight97 kg
Burner connectionR 1½ "
Order no.5518 628 011
Burner output270 - 1450 kW
ControlGas: continuously modulating or two-stage sliding; oil: two-stage sliding
Product ID no.CE-0085AQ1023 · DVGW tested
Mains connection230 V / 400 V / 50 Hz
Burner motor2.2 kW / 4.92 A / 2800 min-1
Oil pump motor0.55 kW / 1.4 A / 230 V / 400 V
Gas burner control unitLMV
Ignition transformer10,000 V / 40 mA
Gas pressure20 - 100 mbar
Gas flow rate25 - 145 m³/h
Turndown ratio1 : 6
Weight105 kg
Burner connectionR 2 "
Order no.5518 629 012
Burner output300 - 1750 kW
ControlGas: continuously modulating or two-stage sliding; oil: two-stage sliding
Product ID no.CE-0085AQ1023 · DVGW tested
Mains connection230 V / 400 V / 50 Hz
Burner motor3.0 kW / 6.45 A / 2800 min-1
Oil pump motor0.55 kW / 1.4 A / 230 V / 400 V
Gas burner control unitLMV
Ignition transformer10,000 V / 40 mA
Gas pressure20 - 100 mbar
Gas flow rate30 - 168 m³/h
Turndown ratio1 : 6
Weight108 kg
Burner connectionR 2 "
Order no.5518 629 016
Burner output700 - 3300 kW
ControlGas: continuously modulating or two-stage sliding; oil: two-stage sliding
Product ID no.CE-0085AQ1023 · DVGW tested
Mains connection400 V / 50 Hz
Burner motor7.5 kW / 15 A / 2800 min-1
Oil pump motor0.8 kW / 2.1 A / 230 V / 400 V
Gas burner control unitLMV
Ignition transformer10,000 V / 40 mA
Gas pressure20 - 100 mbar
Gas flow rate67 - 318 m³/h
Turndown ratio1 : 5
Weight190 kg
Burner connectionR 2½ "
Order no.5518 629 218
Special designs: burner design to TRD 412 · flame tube extension of 150 - 250 mm possible
Output figures for natural gas H (Ho = 10.35 kWh/m³) / heating oil EL (Ho = 10.57 kWh/kg)
Your benefits at a glance
Dual-fuel operation – one burner
Gas and oil combined in one compact housing. Full-scale gas operation, modulating or staged, plus oil operation as a safeguard. Maximum flexibility.
Flexible fuel switching and availability
Straightforward switching between gas and oil operation without conversion work. Protection against supply shortages – maximum operational reliability.
Space-saving design
Compact design saves space in the plant. All components optimally matched – easy installation and maintenance.
Compact design
Designed for medium to large industrial and heating systems. Ideal for critical infrastructure with high availability requirements.
%20(1).png)
.png)
.png)